Free site survey & fixed written quotesGlass, solid & demountable partitionsUK-wide installation teams
0800 088 6248
West Midlands · Fire Rated Partition Walls

Fire Rated Partition Walls in Warwickshire

Whether you are in Warwick, Leamington Spa or a smaller Warwickshire town, we survey, supply and install fire rated partition walls to suit the building and the way your team works.

Guide £75–£125 per m² + VATLead time 1–3 weeksFree survey

Free survey in Warwickshire

Tell us where the site is and we'll arrange a measured survey.

Region
West Midlands
Nation
England
Towns listed
7
Main postcode areas
CV
Typical lead time
1–3 weeks

What should Warwickshire projects plan for?

Rural and edge-of-town premises near Warwick can have awkward access, so we plan panel sizes and delivery times on the survey to avoid surprises on the day.

Offices in Warwick range from first-floor suites above the high street to modern units on the edge of town, and the right partition system depends as much on the building as on the budget.

How much do fire rated partition walls cost in Warwickshire?

£75–£125 per m² + VAT

The required duration (30, 60 or 90 minutes), number of fire board layers, wall height and the extent of fire stopping around services and at the head set the price. Typical lead time: 1–3 weeks. Guide prices, supply and install — fixed after a free survey.

Price my project

Why choose us in Warwickshire?

Covering all of Warwickshire

Survey and installation teams cover Warwick and the wider Warwickshire area, including Warwick and Leamington Spa.

Acoustic bonus

Multi-layer fire walls are also good acoustic walls, so plant rooms and stair enclosures keep noise away from the surrounding office.

Built to the tested system

We follow the manufacturer's tested details for studs, boards, fixings and head, so the wall achieves the classification it is meant to have.

Tested systems, documented

We use manufacturers' tested partition systems and hand over the relevant performance and test evidence at completion.

The most common failures are not the boards but the gaps. Cables, pipes and ducts passing through the wall, sockets and back boxes, deflection heads and junctions with the façade all need fire stopping that is compatible with the wall's rating. We plan penetrations with your M&E contractor, use tested fire-stopping products and record what was installed, with photos taken before the second side is closed. At handover you receive the system classification and the fire-stopping record, which your fire risk assessor and Building Control will want to see.

Key specifications

ClassificationEI 30, EI 60 or EI 90 integrity and insulation, to the tested system
Test standardNon-loadbearing walls tested to BS EN 1364-1 (older data to BS 476-22)
BoardingOne to three layers of 12.5mm or 15mm fire-resistant plasterboard each side
InsulationMineral wool to the system specification

Surveys across Warwickshire

We cover Warwick along with nearby Warwick, Leamington Spa and Nuneaton. Surveys are free and usually take under an hour for a typical office floor.

In England, partition works that affect fire safety or means of escape fall under the Building Regulations, so we flag anything that may need Building Control at survey stage.

How does a project run?

  1. Free survey

    We visit your Warwick premises, measure up, check ceilings, floors and services and talk through how the space needs to work.

  2. Design and fixed price

    You receive a layout, specification and a fixed, itemised quote. Nothing is ordered until you are happy with the drawings.

  3. Manufacture and planning

    Glass and components are made to the surveyed sizes while we plan access, deliveries and any out-of-hours working.

  4. Installation and handover

    The team installs, snags and cleans, then hands over the site with any test evidence and care guidance.

Towns we cover for fire rated partition walls in Warwickshire

Fire Rated Partition Walls in Warwickshire: FAQs

Can you work out of hours at our Warwick office?

Yes. Evening and weekend installation can be arranged in Warwick so the office keeps running. Out-of-hours working usually adds a percentage to the labour cost, which is shown clearly on the quote.

Will our Warwick landlord need to approve the partitions?

If you lease your Warwick office, the lease will usually require landlord consent — often a licence for alterations — before partitions are installed. We supply drawings, specifications and method statements to support the application.

What makes a partition wall fire rated?

A partition wall is fire rated when it is built to a manufacturer's tested system, using the specified studs, fire-resistant boards, insulation, fixings and head detail, and installed exactly as tested. Every service penetration must also be fire stopped with compatible tested products. Using fire board alone does not make a wall fire rated.

How long does a fire rated stud wall last in a fire?

Office fire walls are commonly classified for 30, 60 or 90 minutes, such as EI 30 or EI 60. That figure is the time the tested wall maintained integrity and insulation in a standard furnace test. The duration you need is set by the building's fire strategy and Approved Document B.

Get a guide price for fire rated partition walls in Warwick in under a minute with our quote tool, or ask for a free survey and fixed quote.

Fire Rated Partition Walls in Warwickshire

Free survey, fixed written price and installation around your working hours.

Call Get a quote