Free site survey & fixed written quotesGlass, solid & demountable partitionsUK-wide installation teams
0800 088 6248
Cheshire · CH postcodes

Fire Rated Partition Walls in Chester

Whether it is a short run of glass in a Chester start-up office or a phased fit-out across several floors, we provide fire rated partition walls with clear guide prices up front and a fixed quote after survey.

Guide £75–£125 per m² + VATLead time 1–3 weeksFree survey

Free survey in Chester

Tell us about the space — we'll call to book a measured survey.

Postcode area
CH
County
Cheshire
Region
North West
Population (approx.)
91,000
From our Birmingham office
59 miles
Typical lead time
1–3 weeks

What should Chester offices plan for?

Offices in Chester range from first-floor suites above the high street to modern units on the edge of town, and the right partition system depends as much on the building as on the budget.

In Chester, installations are often completed in a few days, and we can usually start on site soon after drawings are signed off because the survey answers the practical questions early.

Fire Rated Partition Walls prices in Chester

£75–£125 per m² + VAT

The required duration (30, 60 or 90 minutes), number of fire board layers, wall height and the extent of fire stopping around services and at the head set the price. Typical lead time: 1–3 weeks. Guide prices, supply and install — fixed after a free survey.

Price my project

What do you get with us in Chester?

Penetrations planned

Services crossing the wall are coordinated in advance and sealed with tested products, which is where most fire walls actually fail in inspections.

Work around your hours

Evening and weekend installation can be arranged for occupied Chester offices, keeping disruption to a minimum.

Handover records

You receive the system classification, fire-stopping record and photographs, giving your fire risk assessor and Building Control clear evidence of what was built.

Tidy, protected sites

Floors and finishes are protected, waste is removed and the area is cleaned before handover.

Typical fire rated partition walls projects we see in Chester include protected escape corridors, server, comms and plant rooms and tenancy separation walls. We follow the manufacturer's tested details for studs, boards, fixings and head, so the wall achieves the classification it is meant to have.

Key specifications

Test standardNon-loadbearing walls tested to BS EN 1364-1 (older data to BS 476-22)
FramingSteel studs 50–146mm at the system's specified centres
InsulationMineral wool to the system specification

How do surveys work in Chester?

Survey visits across Cheshire — including Chester, Ellesmere Port and Deeside — are free and carry no obligation. We measure, photograph and note services so the quote is accurate first time.

In England, partition works that affect fire safety or means of escape fall under the Building Regulations, so we flag anything that may need Building Control at survey stage.

From survey to handover

  1. Measure and assess

    We take accurate measurements on site in Chester, check the ceiling void and floor, and agree what the new layout must achieve.

  2. Drawings and quote

    We prepare drawings and an itemised fixed price, adjusting the design until it works for your team and budget.

  3. Order and schedule

    Materials are ordered to exact sizes and we agree installation dates, working hours and site rules with you.

  4. Install and sign-off

    We fit the partitions with minimal disruption, complete snagging and walk you through the finished space.

Fire Rated Partition Walls in Chester: FAQs

How much do fire rated partition walls cost in Chester?

Our guide price for fire rated partition walls is £75–£125 per m², supply and install, excluding VAT. The final price for a Chester project depends on the measured size, doors, glass or board specification and access, and is fixed after the free survey.

Will our Chester landlord need to approve the partitions?

If you lease your Chester office, the lease will usually require landlord consent — often a licence for alterations — before partitions are installed. We supply drawings, specifications and method statements to support the application.

What makes a partition wall fire rated?

A partition wall is fire rated when it is built to a manufacturer's tested system, using the specified studs, fire-resistant boards, insulation, fixings and head detail, and installed exactly as tested. Every service penetration must also be fire stopped with compatible tested products. Using fire board alone does not make a wall fire rated.

Do fire rated walls need fire doors?

Yes. A door in a fire rated wall must be a fire door set tested to the same or appropriate rating, with compatible frame, hinges, closer, seals and signage. A standard door undermines the wall. We supply complete tested door sets and can check existing doors for suitability.

Ready to plan fire rated partition walls in Chester? Send a few details or call us and we will book a survey at a time that suits.

Fire Rated Partition Walls in Chester

Free survey, fixed written price and installation around your working hours.

Call Get a quote