Free site survey & fixed written quotesGlass, solid & demountable partitionsUK-wide installation teams
0800 088 6248
East of England · Fire Rated Partition Walls

Fire Rated Partition Walls in Essex

From city offices to business parks and converted buildings, we provide fire rated partition walls throughout Essex and the wider East of England region.

Guide £75–£125 per m² + VATLead time 1–3 weeksFree survey

Free survey in Essex

Tell us where the site is and we'll arrange a measured survey.

Region
East of England
Nation
England
Towns listed
10
Main postcode areas
CM, CO, RM, SS
Typical lead time
1–3 weeks

What should Essex projects plan for?

Business parks around Chelmsford usually offer open floorplates with suspended ceilings, which suit glazed meeting rooms and full-height partitions once the ceiling void and services have been checked.

Many Chelmsford workplaces are owner-occupied, which makes it easier to choose systems for the long term — acoustic glass for meeting rooms, for example, rather than the cheapest option.

How much do fire rated partition walls cost in Essex?

£75–£125 per m² + VAT

The required duration (30, 60 or 90 minutes), number of fire board layers, wall height and the extent of fire stopping around services and at the head set the price. Typical lead time: 1–3 weeks. Guide prices, supply and install — fixed after a free survey.

Price my project

Why choose us in Essex?

Work around your hours

Evening and weekend installation can be arranged for occupied Chelmsford offices, keeping disruption to a minimum.

Built to the tested system

We follow the manufacturer's tested details for studs, boards, fixings and head, so the wall achieves the classification it is meant to have.

Penetrations planned

Services crossing the wall are coordinated in advance and sealed with tested products, which is where most fire walls actually fail in inspections.

One point of contact

A single project contact handles survey, drawings, ordering and installation, so you are not chasing different trades.

Office fit-outs often include walls that have a fire job to do: corridor walls on a protected escape route, enclosures around stairs, risers and plant, and walls that separate tenancies or compartments. A fire rated partition wall is built using the board manufacturer's tested system, specifying stud size, board type and number of layers, fixings, insulation and how the head and junctions are detailed. Follow that system and the wall carries its classified rating; deviate from it and the rating no longer applies.

Key specifications

ClassificationEI 30, EI 60 or EI 90 integrity and insulation, to the tested system
Test standardNon-loadbearing walls tested to BS EN 1364-1 (older data to BS 476-22)
BoardingOne to three layers of 12.5mm or 15mm fire-resistant plasterboard each side
Acoustic performanceApprox. Rw 45–55 dB depending on build-up (lab)

Surveys across Essex

Survey visits across Essex — including Chelmsford, Chelmsford and Colchester — are free and carry no obligation. We measure, photograph and note services so the quote is accurate first time.

In England, partition works that affect fire safety or means of escape fall under the Building Regulations, so we flag anything that may need Building Control at survey stage.

How does a project run?

  1. Measure and assess

    We take accurate measurements on site in Chelmsford, check the ceiling void and floor, and agree what the new layout must achieve.

  2. Design and fixed price

    You receive a layout, specification and a fixed, itemised quote. Nothing is ordered until you are happy with the drawings.

  3. Production and logistics

    Made-to-measure panels are produced and we book deliveries, lifts and parking around your building.

  4. Installation and handover

    The team installs, snags and cleans, then hands over the site with any test evidence and care guidance.

Towns we cover for fire rated partition walls in Essex

Fire Rated Partition Walls in Essex: FAQs

How much do fire rated partition walls cost in Chelmsford?

Our guide price for fire rated partition walls is £75–£125 per m², supply and install, excluding VAT. The final price for a Chelmsford project depends on the measured size, doors, glass or board specification and access, and is fixed after the free survey.

How soon can you start on a Chelmsford project?

Typical lead time for fire rated partition walls is 1–3 weeks from signed-off drawings, mostly because materials are made to measure. Installation itself is usually a matter of days for a typical office, and we can phase work around a Chelmsford office that stays open.

How much does a fire rated partition wall cost?

Fire rated partition walls typically cost £75–£125 per m² supplied and installed, excluding VAT. A 30-minute wall with one layer of fire board each side sits at the lower end; 60 or 90-minute walls with multiple layers and extensive fire stopping sit at the top. Fire doors are priced separately. We confirm a fixed price after a free survey.

How long does a fire rated stud wall last in a fire?

Office fire walls are commonly classified for 30, 60 or 90 minutes, such as EI 30 or EI 60. That figure is the time the tested wall maintained integrity and insulation in a standard furnace test. The duration you need is set by the building's fire strategy and Approved Document B.

Ready to plan fire rated partition walls in Chelmsford? Send a few details or call us and we will book a survey at a time that suits.

Fire Rated Partition Walls in Essex

Free survey, fixed written price and installation around your working hours.

Call Get a quote