Free site survey & fixed written quotesGlass, solid & demountable partitionsUK-wide installation teams
0800 088 6248
Hampshire · PO postcodes

Fire Rated Partition Walls for Havant offices

Looking for fire rated partition walls in the PO postcode area? We design and install partitioning for Havant workplaces of every size, and we can usually visit to measure up quickly anywhere in Hampshire.

Guide £75–£125 per m² + VATLead time 1–3 weeksFree survey

Free survey in Havant

Tell us about the space — we'll call to book a measured survey.

Postcode area
PO
County
Hampshire
Region
South East
Population (approx.)
46,000
From our Birmingham office
124 miles
Typical lead time
1–3 weeks

What should Havant offices plan for?

Smaller floorplates in Havant make every metre count, so we often recommend glass that keeps daylight moving across the office while still giving managers a private room.

Across Havant we see a lot of mixed-use space — offices next to workshops, clinics or showrooms — where partitions have to deal with noise, dust or fire separation as well as privacy.

What do fire rated partition walls cost in Havant?

£75–£125 per m² + VAT

The required duration (30, 60 or 90 minutes), number of fire board layers, wall height and the extent of fire stopping around services and at the head set the price. Typical lead time: 1–3 weeks. Guide prices, supply and install — fixed after a free survey.

Price my project

Why do Havant businesses choose us?

Acoustic bonus

Multi-layer fire walls are also good acoustic walls, so plant rooms and stair enclosures keep noise away from the surrounding office.

Handover records

You receive the system classification, fire-stopping record and photographs, giving your fire risk assessor and Building Control clear evidence of what was built.

Free survey in Havant

We measure the space, check ceilings, floors and services, and talk through how you want the office to work before anything is priced.

Tested systems, documented

We use manufacturers' tested partition systems and hand over the relevant performance and test evidence at completion.

Typical fire rated partition walls projects we see in Havant include protected escape corridors, server, comms and plant rooms and tenancy separation walls. Services crossing the wall are coordinated in advance and sealed with tested products, which is where most fire walls actually fail in inspections.

Specification highlights

Test standardNon-loadbearing walls tested to BS EN 1364-1 (older data to BS 476-22)
FramingSteel studs 50–146mm at the system's specified centres
Fire stoppingTested collars, wraps, sealants and batts for every penetration

How do surveys work in Havant?

If you are in Havant or close by in Portsmouth or Chichester, book a free survey and we will come and measure. You will receive drawings and a fixed price before you commit to anything.

In England, partition works that affect fire safety or means of escape fall under the Building Regulations, so we flag anything that may need Building Control at survey stage.

How does a Havant project run?

  1. Free survey

    We visit your Havant premises, measure up, check ceilings, floors and services and talk through how the space needs to work.

  2. Drawings and quote

    We prepare drawings and an itemised fixed price, adjusting the design until it works for your team and budget.

  3. Order and schedule

    Materials are ordered to exact sizes and we agree installation dates, working hours and site rules with you.

  4. Installation and handover

    The team installs, snags and cleans, then hands over the site with any test evidence and care guidance.

Fire Rated Partition Walls in Havant: FAQs

How soon can you start on a Havant project?

Typical lead time for fire rated partition walls is 1–3 weeks from signed-off drawings, mostly because materials are made to measure. Installation itself is usually a matter of days for a typical office, and we can phase work around a Havant office that stays open.

Do you cover areas near Havant?

Yes. As well as Havant we regularly cover Portsmouth, Fareham and Chichester, plus the rest of Hampshire and South East. Survey and installation teams are arranged regionally.

How much does a fire rated partition wall cost?

Fire rated partition walls typically cost £75–£125 per m² supplied and installed, excluding VAT. A 30-minute wall with one layer of fire board each side sits at the lower end; 60 or 90-minute walls with multiple layers and extensive fire stopping sit at the top. Fire doors are priced separately. We confirm a fixed price after a free survey.

Who signs off a fire rated partition wall?

Where walls affect escape routes or compartmentation, Building Control normally reviews and inspects the work. Your fire risk assessor will also want evidence for the fire risk assessment. We hand over the system classification, fire-stopping records and photographs so both can verify what was built.

Speak to us about fire rated partition walls for your Havant premises — free survey, clear drawings and a fixed price before work starts.

Fire Rated Partition Walls in Havant

Free survey, fixed written price and installation around your working hours.

Call Get a quote